Smart ups 3000 rm xl software




















Simulates utility power to provide the highest degree of compatibility for active PFC power factor corrected servers and sensitive electronics. Customize network shutdown and reboot sequence of connected servers and UPSs.

Eliminates humming and heat generated when powering tube lights and fans. Prolongs battery life by regulating the charge voltage according to battery temperature. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR. Network manageable Most models provide remote power management options of the UPS over the network. Serial connectivity Provides management of the UPS via a serial port. Audible alarms Provides notification of changing utility power and UPS conditions.

LED status indicators Quickly understand unit and power status with visual indicators. Marketing features. Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected PFC power supplies. Save time with easy and convenient remote accessibility Network manageable via serial, USB or optional ethernet. Avoids costly power problems by keeping your IT equipment and data safe and available Network grade power conditioning protects from damaging surges and disruptive noise.

Reliable battery back-up capacity to power through outages or gracefully shutdown systems. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement.

Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Smarter productivity with ability to tailor to your specific application needs Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.

Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.

Disconnected battery notification Warns when a battery is not available to provide backup power. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Boost and Trim Automatic Voltage Regulation AVR Gives higher application availability by correcting low and high voltage conditions without using the battery not available on all models.

Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Many do not have NMC embedded. Marketing features.

Avoids costly power problems by keeping your IT equipment and data protected and available. Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events. Network manageable via serial, USB or Ethernet.

Low operating and maintenance costs with proven reliability and intelligent battery management. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement.

Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected PFC power supplies.

Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse. Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used. Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling. Cold-start capable Provides temporary battery power when the utility power is out.

Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Disconnected battery notification Warns when a battery is not available to provide backup power. Audible alarms Provides notification of changing utility power and UPS power conditions. Predictive failure notification. Provides early-warning fault analysis ensuring proactive component replacement. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP. Disconnected battery notification Warns when a battery is not available to provide backup power. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Boost and Trim Automatic Voltage Regulation AVR Gives higher application availability by correcting low and high voltage conditions without using the battery not available on all models.

Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Resettable circuit breakers Enables a quick recovery from overload events. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance.

User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Predictive failure notification. Provides early-warning fault analysis ensuring proactive component replacement.

Virgin Islands. Technical Specifications Print. Max Configurable Power Watts 2. Load Crest Factor Up to 5 : 1. Topology Line interactive. Waveform type Sine wave. Maximum Output Current Input voltage range for main operations 86 - Adjustable, 92 - V. Number of Power Cords 1. Battery type Lead-acid battery. Typical recharge time 3hour s. Replacement Battery RBC Thanks Michael. Kevin Apr 24, at UTC. Thanks, Kevin. Let us know if you need assistance configuring.

This topic has been locked by an administrator and is no longer open for commenting.



0コメント

  • 1000 / 1000